Choosing a heat pump18 min read

Best heat pump for a new build with underfloor heating

Updated on

Outdoor unit of an EXINDA residential air-to-water heat pump

TL;DR

The short answer

The best heat pump for new build projects with underfloor heating is an air-to-water unit sized from a heat-loss calculation, efficient at 35 °C flow, and planned with its hydraulics, hot water, cooling and electrical supply before the screed and facade are finished. In a well-insulated house the bigger risk is too much capacity, not too little. CENTRO-GAS, the exclusive Serbian distributor of EXINDA heat pumps, sizes, installs and commissions these systems from Novi Sad, starting at design stage.

Why a new build changes the heat pump choice

Choosing the best heat pump for new build projects with underfloor heating depends on choices fixed early by drawings, screed and facade. CENTRO-GAS, a Novi Sad industrial heating company, is the exclusive Serbian distributor of EXINDA air to water heat pump units.

Seven requirements decide the result, from capacity and flow temperature to commissioning, and each one has a construction stage after which it is expensive to change, so the installer matters more than the brand sticker. For size bands, see the heat pump sizing guide.

The three checks that matter most

  • Size the unit from a heat-loss calculation at your town's design temperature (the coldest outdoor temperature it is planned for), not from floor area.
  • Compare SCOP, the yearly ratio of heat delivered to electricity used, with water flowing to the floors at 35 °C.
  • Plan the buffer tank, hot water and electrical supply with the installer before the screed goes in.

Criteria scoring table

Each row scores a requirement for this home, not a brand.

Criteria for a new build with underfloor heating
CriterionWhy it matters in a new build with underfloor heatingWhat to decide and whenWhat a good answer sounds like
Capacity from heat lossA well-insulated house can need far less capacity than floor-area bands suggestUnit size, at design stageSized from a room-by-room heat-loss calculation at the local design temperature
Efficiency at 35 °C flowFloors run at 30 to 35 °C flow, the range where a heat pump works at its most efficientWhich unit, at design stageSCOP stated at 35 °C flow for the unit on offer
Hydraulic designFlow to every floor circuit depends on the tank, pumps and vesselBuffer tank and pump group, at design stageHydraulics drawn with the unit, buffer tank decision explained for your zones
Domestic hot waterHot water needs a higher temperature than the floor circuitTank size and heating priority, at design stageTank size and priority set for your household, not a default
Summer coolingCooling through the floor is limited by condensationFan coils or floor cooling, at design stageFan coils where cooling matters, floor cooling only with dew point control
Supply, placement and noiseCables, a base and drainage are hard to add once the facade is doneSupply, position and base, at rough-inSupply matched to unit size, rated sound power read from the datasheet
Commissioning and serviceUnderfloor systems succeed or fail on commissioningWho commissions and services, before you buyThe same local team installs, commissions and services the system

Heat Geek names the system design flow temperature as the single biggest factor in efficiency. As a general rule, heat pumps deliver roughly 3 to 4 times more heat energy than the electricity they consume.

Capacity from a heat-loss calculation, not floor area

Capacity should come from the heat loss of the house at its local design temperature. A well-insulated new build can need far less capacity than floor-area bands suggest. According to NYSERDA, New York's state energy agency, an oversized heat pump costs more to buy and more to operate than a right-sized one.

Why an oversized unit costs you efficiency

Low-load cycling happens when the smallest output a heat pump can run at is still higher than the heat the house needs, so it switches on and off. The NYSERDA fact sheet says the effects on energy use and comfort begin at 120% of the building load, and constant cycling adds wear and tear.

Heat Geek, which trains UK installers, traces the problem back to boilers: "The boiler industry has left a huge legacy of over-sized heat sources."

The guide to a 100 to 130 m² house covers sizing at standard scale.

Design temperatures used in the heat-loss calculation

The calculation starts from the coldest outdoor temperature expected where the house stands. The CENTRO-GAS sizing calculator uses these values.

Design temperatures used in the heat-loss calculation
LocationDesign temperature
Belgrade and Nišminus 12 °C
Novi Sad and Zrenjaninminus 15 °C
Sombor and Užiceminus 16 °C
Suboticaminus 18 °C
Mountain areasminus 20 °C

Heat Geek also warns that a surveyor who has not measured every window, wall and door has not done a heat-loss calculation.

What this means for your home: Ask for a room-by-room heat-loss calculation at your town's design temperature before any unit is quoted. Correct capacity depends on insulation, climate and the heating system, and CENTRO-GAS provides the sizing consultation.

Seasonal efficiency at 35 °C flow

Underfloor heating lets a heat pump work at its most efficient because floors run at 30 to 35 °C flow. Flow temperature is the temperature of the water the heat pump sends into the floor circuits. Reonic's SCOP guide explains that underfloor heating can run as low as 35 °C and that lower flow temperatures make the compressor work less hard.

In the same Reonic guide, Manpreet Singh puts it plainly: "Flow temperature affects SCOP more than almost any other design decision."

What the EXINDA SCOP figures show

SCOP is the total heat a heat pump delivers over a year divided by the electricity it uses in that year. The TÜV Rheinland ErP test report (EN 14825) lists SCOP 5.56 at 35 °C for the 6 kW unit. The 12 kW unit is rated at SCOP 4.91 at 35 °C.

All EXINDA residential units use R290 refrigerant (propane), DC inverter compressors and a monoblock design. An inverter compressor changes its speed to match the heat the house needs, and a monoblock unit keeps the whole refrigerant circuit outdoors and connects to the house through water pipes.

Floors versus radiators

A heat pump can heat rooms through radiators or underfloor heating, as the Energy Saving Trust explains. Older radiator systems may need higher flow temperatures or emitter upgrades, so an existing house is a different decision.

That case is covered in the guide for old houses with radiators.

What this means for your home: Ask every supplier for SCOP at 35 °C flow, the figure that matches your floors. A rating quoted only at higher flow temperatures says less about how the unit will run in your house.

Hydraulic design: buffer tank, pump group and expansion vessel

The hydraulics decide whether every floor circuit gets the right flow, so they are designed together with the heat pump. CENTRO-GAS supplies and installs buffer tanks, pump groups, expansion vessels, valves and fittings with the unit, and each part needs space and pipework planned before the screed.

What each component does

A buffer tank is an insulated water store between the heat pump and the floor circuits. A pump group is the set of circulation pump and valves that moves water through a heating circuit. An expansion vessel absorbs the change in water volume as the system heats up, which keeps the pressure stable.

Caleffi's idronics guide to thermal storage shows that a buffer tank can stop a heat pump from short cycling, and that a longer minimum running time calls for a larger tank.

When a buffer tank is needed

Many small zones with their own thermostats are the typical case. Caleffi's worked example pairs a heat pump of about 14 kW (48,000 Btu/hr) with a smallest zone that needs only about 0.7 kW (2,500 Btu/hr), roughly 5% of the unit's output. For a modulating unit the tank is sized from its minimum stable output rather than its full output, so an inverter unit usually needs a smaller tank, and the installer decides per system.

What this means for your home: Ask for a hydraulic drawing with the quote, showing whether a buffer tank is needed for your zones and why.

Domestic hot water at a higher temperature

Hot water needs a higher temperature than the floor circuit, so the installer sets the tank size and the heating priority for your household. The tank and the floors share one outdoor unit, so both plans are drawn together. According to the Energy Saving Trust, a heat pump can also heat water stored in a cylinder for taps, showers and baths.

Tank size and heating priority

Heating priority is the control rule that decides when the heat pump stops feeding the floors and heats the tank instead. The installer sets the tank size for your household, so it is a design decision, not a standard part.

Stored hot water also needs care. The REHVA Journal notes that hot water heat pump systems need careful management to prevent Legionella.

What R290 adds for hot water

R290 units run comfortably to 60 °C flow, well above the 30 to 35 °C the floors need. All EXINDA residential units are compatible with domestic hot water tanks, so one outdoor unit serves both the floor circuits and the tank.

What this means for your home: Tell the installer how many people live in the house and how they use hot water, so the tank and priority settings fit your routine. Ask also how the system protects stored water against Legionella.

Summer cooling and its limits on floors

The same air-to-water heat pump can also cool the house. Fraunhofer IBP describes cooling rooms through the existing heating system by running its heat pump in reverse. Fan coils are the usual way to cool, while cooling through the floor is limited by condensation and needs controlled flow temperatures.

Fan coils versus floor cooling

A fan coil is an indoor unit with a fan that blows room air over a coil carrying cooled water. Better Homes BC notes that a separate indoor fan coil unit is typically used for cooling with air-to-water systems.

Floor cooling needs dew point control. A Purmo Group guide to underfloor cooling explains that the circulating water must not fall below a set temperature, to prevent condensation on the floor surface, and recommends a minimum floor surface temperature of 18 to 20 °C.

A design-stage decision

Fraunhofer researchers list the challenges of cooling through a heating system: preventing mould by regulating temperature to the dew point, keeping floors from feeling unpleasantly cold, and the cooling capacity each system can actually deliver. Decide on cooling at design stage, because fan coils need their own positions and pipework planned with the rest of the system.

What this means for your home: If summer comfort matters, plan fan coils for the rooms that need cooling and treat floor cooling as a mild extra, not as air conditioning.

Electrical supply, placement and noise planned before the facade

Electrical supply, outdoor unit position, base and condensate drainage should be fixed before the facade and landscaping are finished, at rough-in at the latest. Each one is a line on a drawing at design stage and a disruptive change once walls are rendered and paths are laid.

Electrical supply sized at design stage

According to the EXINDA product data, the 6, 9 and 12 kW units run on a 220-240V single-phase supply (minimum circuit ampacity of 16 A, 21 A and 28 A respectively), and the 15 kW unit needs a 380-415V three-phase supply (minimum circuit ampacity 14 A). The 20 kW unit is a three-phase 380-415V monoblock requiring at least 20 A, so the electrician sizes the supply at design stage. Larger homes that need more capacity are covered in the guide for villas and two-family houses.

Outdoor unit position, base and condensate drainage

Agree the outdoor unit's position, its base and the route for condensate drainage before landscaping starts. Mark all three on the drawings so the builder keeps the space and the pipe routes free.

Checking rated sound power

Check the rated sound power on the datasheet of every unit you shortlist. Compare it with where the unit will sit relative to bedrooms, terraces and neighbours.

What this means for your home: Give the electrician the planned unit size before the cables go in, and fix the outdoor unit position before the facade and paving are finished.

Local commissioning and service

Underfloor heat pump systems succeed or fail on commissioning, which covers the heating curve, the flow rates in each floor circuit and coordination with the screed drying programme. CENTRO-GAS commissions and services its own installations, backed by an established industrial burner and heat-system business with a deep technical team.

What commissioning covers

The heating curve is the setting that links flow temperature to outdoor temperature, so the water runs warmer only when it is colder outside. OpenEnergyMonitor reports that many monitored systems run hotter than they need to, and that dropping the curve on one example system should improve performance significantly.

The flow rates in each floor circuit are set and checked at the same stage. For the screed, one manufacturer's screed guidance allows underfloor heating to be commissioned from 7 days to help its screed dry, so follow the programme for the screed actually used.

What EXINDA brings to the unit

R290 is a low-GWP refrigerant with a GWP of 3. GWP (global warming potential) measures how strongly a gas warms the climate if it escapes, so a lower number is better. EXINDA units carry a Heat Pump KEYMARK certificate (BRE Global) and a TÜV Rheinland certificate under the RED 2014/53/EU directive, with SCOP measured by TÜV Rheinland per EN 14825. The units operate down to minus 25 °C and are tested in climate chambers to minus 40 °C.

What this means for your home: Ask who will set the heating curve and who answers the phone when the first winter starts. The answer should be the same local team.

The CENTRO-GAS option for this home

For a well-insulated new build of 100 to 130 m² with underfloor heating, CENTRO-GAS installs the Exinda 9 kW unit, with the 12 kW unit for larger homes. The final capacity is confirmed in a sizing consultation.

When to bring the installer into a new build

Bring the installer in at design stage, because the best heat pump for new build projects depends on decisions that each later construction stage locks in. Better Homes BC rates air-water systems as most suitable for new construction, and early planning is how a new build uses that advantage.

Design stage

The heat-loss calculation sets the unit size and the hot water tank size. The decision that is expensive to change later is the unit capacity.

Rough-in

Pipework, electrical supply and the outdoor unit position go in. The decision that is expensive to change later is the cable and pipe routes through walls and ground.

Screed

The floor circuits are tested before the screed is poured. One screed maker's post-installation guide turns the system off to cool for 48 hours before moisture testing. The decision that is expensive to change later is the floor circuit layout.

Commissioning

The installer sets the heating curve and hands the system over. The decision that is expensive to change later is who commissions and services it, since that team answers for the result.

Getting started

The first step toward the best heat pump for new build projects is a heat-loss based sizing consultation with the installer who will commission the system. Start while unit size, hydraulics and supply can still change on paper. CENTRO-GAS runs this consultation from Novi Sad and follows the project through installation, commissioning and service.

Installation packages

CENTRO-GAS plans three installation packages, Basic, Standard and Premium, each with a service contract and priced as a complete project rather than a box. Total cost of ownership matters more than the unit price, so ask what each tier covers before comparing offers. The Energy Saving Trust rates heat pumps as more than three times more efficient than a gas or oil boiler.

Subsidy help

State subsidies for energy-efficient heating can cover a significant share of the cost. CENTRO-GAS helps you check current program requirements and issues the pro forma invoice (predračun) you need to apply. Subsidy programs change, so the terms must be confirmed at application time.

Before you contact an installer

Have these ready for the first meeting:

  • floor plan and sections of the house
  • insulation specification for walls, roof and windows
  • location, which sets the design temperature
  • planned heating zones, cooling needs and hot water use
  • the builder's planned dates for rough-in and the screed

Frequently asked questions

01

What is the best heat pump for underfloor heating?

The best heat pump for underfloor heating is an air-to-water unit sized from a heat-loss calculation and rated for high seasonal efficiency at 35 °C flow. Floors run at 30 to 35 °C, the range where heat pumps work most efficiently. Compare SCOP at 35 °C, check the hydraulics and hot water plan, and choose an installer who commissions and services the system locally.

02

Why do heat pumps work best with underfloor heating?

Heat pumps work best with underfloor heating because floors need only 30 to 35 °C flow, and a heat pump becomes more efficient as the flow temperature falls. The compressor works less hard to reach a low water temperature. Older radiators often need higher flow temperatures, which is why a radiator house is assessed separately from a new build with heated floors.

03

Can a heat pump be oversized in a new build?

Yes. A well-insulated new build can need far less capacity than floor-area bands suggest, and an oversized unit cycles on and off, which wastes energy and adds wear. The fix is a room-by-room heat-loss calculation at the local design temperature, for example minus 15 °C in Novi Sad, before any unit is chosen.

04

Do I need a buffer tank with underfloor heating and a heat pump?

Not always. A buffer tank helps most when the floors are split into many small zones with their own thermostats, because each zone may need only a small share of the unit's output and the heat pump would otherwise cycle on and off. Inverter units reduce the need, so the installer decides per system at design stage.

05

Can underfloor heating cool the house in summer with a heat pump?

Yes, within limits. An air-to-water heat pump can run in reverse and send cool water through the floor, but the floor must stay above the dew point to avoid condensation, so its cooling capacity is limited. Fan coils are the usual choice where real cooling matters, and the decision belongs at design stage with the rest of the system.

06

When should the heat pump be chosen during a new build project?

Choose the heat pump at design stage, before rough-in starts. The heat-loss calculation and the unit and tank sizes come first, followed by pipework, electrical supply and outdoor unit position at rough-in, floor circuit testing before the screed, and the heating curve at commissioning. Each later stage makes a change more expensive.

Key terminology

Flow temperature
Flow temperature is the temperature of the water a heat pump sends into the heating circuit. Underfloor heating runs at 30 to 35 °C flow, lower than older radiators usually need.
Design temperature
Design temperature is the coldest outdoor temperature a heat-loss calculation plans for. The CENTRO-GAS sizing calculator uses minus 12 °C for Belgrade and minus 18 °C for Subotica.
SCOP
SCOP, the seasonal coefficient of performance, is the heat a heat pump delivers over a year divided by the electricity it uses in that year. A higher SCOP means more heat for each unit of electricity.
Monoblock
A monoblock heat pump keeps its whole refrigerant circuit in one outdoor unit and connects to the house through water pipes. All EXINDA residential units use a monoblock design.
R290
R290 is propane used as a refrigerant, with a GWP of 3. R290 units run comfortably to 60 °C flow, which covers domestic hot water.
Inverter
An inverter compressor changes its speed to match the heat the house needs instead of only switching fully on and off. All EXINDA residential units use DC inverter compressors.
Buffer tank
A buffer tank is an insulated water store between the heat pump and the heating circuits. Larger buffer tanks give the heat pump longer running cycles, which helps systems with many small zones.
Next step

Building now? Book a free CENTRO-GAS design consultation before the screed goes in, so the heat pump, buffer tank and floor circuits are sized together. Run the CENTRO-GAS sizing calculator for a first estimate, then request a quote with installation at centro-gas@centro-gas.com or +381 63 371 419.